Sign In | Join Free | My china-telecommunications.com
china-telecommunications.com
Products
Search by Category
Home >

Black Top ESR Tube with Additive of 3.8% Sodium Cirtrate (0.129mol/L)

Categories Blood Sample Collection Tube
Certification: FSC, ISO13485, CE, DOC
Place of Origin: China
MOQ: 30,000 Pcs
Price: Negotiable
Payment Terms: L/C, T/T, Western Union
Supply Ability: 10,000,000 Pieces Per Month
Delivery Time: 20-25 Days
Packaging Details: 100 Pcs/Tray, 18 Trays/Ctn
Item Name: Black Top ESR Tube with Additive of 3.8% Sodium Cirtrate (0.129mol/L)
Cap: Black
Additive: 3.8% Sodium Cirtrate (0.129mol/L)
Tube Material: PET/Glass
Label: Paper/Transparent/UV Printing
Tube Size: 13*75mm, 8*120mm
Volume: 1.28ml, 1.6ml, 2.0ml, 2.4ml, 3ml
Shelf Life: 2 Years (Glass), 1 Year (PET)
Category: Whole Blood Collection Tube
Classification: ESR Tube
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

Black Top ESR Tube with Additive of 3.8% Sodium Cirtrate (0.129mol/L)

Black Top ESR Tube with Additive of 3.8% Sodium Cirtrate (0.129mol/L)

【ESR Tube Introduction】


13×75mm ESR test tube is specially used in blood collection and anticoagulation for Automated Erythrocyte Sedimentation Rate Analyzers sedimentation rate test with the mixing ratio of 1 part sodium citrate to 4 parts blood, by Westergren method.
8×120mm ESR sample tube is applicable to various Automated Erythrocyte Sedimentation Rate Analyzers. Due to little volume and negative pressure inside the tube, it needs some time for blood collection. Do patiently wait until blood stops flowing into the tube, then completely mix the anticoagulation and additive by turning the tube upside down for 6-8 times. Inappropriate mixing will cause hemolysis, coagulation or blood bubble and influence the test result.

【ESR Tube Categories】


CategoryTypeAdditiveCap ColorTube MaterialTube SizeTest Item
Serum Blood Collection TubePlain TubePlainGlass/Plastic13*75mmClinical Biochemistry,
Immunology and Serology Test
13*100mm
16*100mm
Pro-coagulation TubeClot ActivatorGlass/Plastic13*75mm
13*100mm
16*100mm
Gel & Clot Activator TubeGel & CoagulantGlass/Plastic13*75mm
13*100mm
16*100mm
Whole Blood Collection TubeEDTA TubeSprayed K2EDTA / K3EDTAGlass/Plastic13*75mm
Haematology Test (Blood Routine Examination)
13*100mm
16*100mm
ESR Tube3.8% Sodium Citrate Buffer (0.129mol/L), 3.2% Sodium Citrate Buffer (0.109mol/L)Glass/Plastic13*75mm
Erythrocyte Sedimentation Rate Test
13*100mm
16*100mm
Plasma Blood Collection TubeCoagulation Tube

3.2% Sodium Citrate Buffer (0.109mol/L)



Glass/Plastic13*75mmCoagulation Function Test
13*100mm
16*100mm
Heparin Tube

Sodium Heparin / Lithium Heparin



Glass/Plastic13*75mmClinical Biochamistry for Emergency Treatment, Blood Rheology Test
13*100mm
16*100mm
Glucose TubeSodium Fluoride & EDTA K2 / Sodium Fluoride & EDTA Na2Glass/Plastic13*75mm
Blood Glucose and Lactate Test
13*100mm
16*100mm










【ESR Tube Sequence】



Attentions:

  • It’s critical to fix the needle holder and needle wing of the scalp vein set.
  • Do not use the tourniquet more than 1 minute.
  • Immediately mix the blood and additive inside the vacuum blood tubes after blood collection.
  • Collect blood as the above sequence.


【ESR Tube Use Instructions】


Step 1: Choose the right specification pen-type blood collection needle and take off the white cover of the vacutainer needle.

Step 2: Screw the tube needle into the needle holder.

Step 3: Take off the color cover of the needle and choose the human proper vein to puncture. Insert the ESR tube Westergren into the holder and press to puncture the tube stopper.

Step 4: After the vacuum in the tube used up, blood will stop flowing into the tube. Take out the ESR Westergren tube from the holder.

Step 5: Right after the blood tube taken out, turn it upside down 5-6 times to mix the blood and additive inside completely. Intense turning is strictly prohibited.



Step1: Screw tight the connection between tube needle and the soft pipe to prevent leakage of vacuum or blood during the blood collection.
Step 2: Choose the human proper vein to puncture and blood flow could be seen.
Step 3: Insert another side of the venous blood collection needle into the tube stopper.
Step 4: When 0.5ml short of the rated blood volume in the final tube, take out the needle from the vein. Take off the needle from Westergren tube after blood in the soft pipe all flows into the blood draw tube.
Step 5: Right after the vacutainer needle taken out, turn the blood sampling tube upside down 5-6 times to mix the blood and additive inside completely. Intense turning is strictly prohibited.


Remark: The steps of correctly preparing high quality serum with Gel/Clot activator tube.



【ESR Tube Related Products】



Venous Blood Collection Needle



Non-Vacuum Blood Collection Tubes



Mini Blood Collection Tube


Buy Black Top ESR Tube with Additive of 3.8% Sodium Cirtrate (0.129mol/L) at wholesale prices
Send your message to this supplier
 
*From:
*To: Suzhou Summit Medical Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0