Brand Name: | Sinuo |
Model Number: | SN122601 |
Certification: | Calibration Certificate (Cost Additional) |
Place of Origin: | China |
MOQ: | 1 |
Price: | Customized |
Payment Terms: | L/C, T/T |
Supply Ability: | 10 Sets Per Month |
Delivery Time: | 20 Days |
Packaging Details: | Plywood |
Detection range of filtration efficiency test: | 0.001% ~ 99.999% |
Accuracy: | Level 1 |
Flowmeter range of filter efficiency test: | 10 ~ 100 L / min |
Flowmeter accuracy: | Level 2.5 |
Sampling frequency of filtration efficiency test: | 1-9999 times / min |
Particle concentration of filtration efficiency test: | 0.001-200 mg / m³ |
Company Info. |
Sinuo Testing Equipment Co. , Limited |
Verified Supplier |
View Contact Details |
Product List |
Respirator Protective Clothing Particle Filtration Efficiency Test Equipment
Product overview:
Particle filtration efficiency testing equipment is used to test the filtration efficiency of particulate matter for daily protective masks and medical masks, and determine the obstruction performance of ordinary fabrics and medical protective masks against the constant flow of airflow.
It is widely adopted by medical device inspection center, safety protection inspection center, labor protection inspection center, drug inspection center, disease prevention and control center, textile testing center, hospital, mask manufacturing enterprises, etc.
Technical Parameters:
1. Range: (10 ~ 100) L / min, order of accuracy 2.5.
2. Filter efficiency test detection range: (0.001 ~ 99.999)%.
3. Filter efficiency test sampling frequency: 1-9999 times / min,
can be set arbitrarily.
4. Filtration efficiency test particle concentration: (0.001 ~ 200)
mg / m3.
5. Differential pressure transducer range: 0 ~ 1000 pa.
6. Median diameter: salt particles (0.075 ± 0.02) μ m, oil
particles (0.185 ± 0.02) μ m. Geometric criteria for particle size
distribution
Deviation: salt particles ≤ 1.86, oil particles ≤ 1.60. Dynamic
detection range: 0.001-100mg / m3, accuracy 1%.
7. Test area: 100 cm2.
8. Aerosol agent: sodium chloride (optional with DOP, DEHS, wax
oil, corn oil).
9. Aerosol concentrations: 12-20 mg / m3 (salty), 50-200 mg / m3
(oily).
10. Power supply: AC220V 50Hz.
11. Control mode: touch screen computer control, through the touch
screen or mouse operation. Operation is simple and intuitive.
12. After the test is completed, PDF test reports are automatically
generated and test data can be exported without fear of data loss.
13. Simple operation: The user only needs to put the object to be
tested into the fixture, press the button, and the system adjusts
the test flow through the controller (PLC).
Automatic detection of filtration efficiency, the whole process is
simple, fast and efficient.
Name | Specifications |
Detection range of filtration efficiency test | 0.001% ~ 99.999% |
Accuracy | Level 1 |
Flowmeter range of filter efficiency test | 10 ~ 100 L / min |
Flowmeter accuracy | Level 2.5 |
Sampling frequency of filtration efficiency test | 1-9999 times / min |
Particle concentration of filtration efficiency test | 0.001-200 mg / m³ |
Counting median diameter | Salt particles (0.075 ± 0.02) μm Oil particles (0.185 ± 0.02) μm |
Geometric standard of particle size distribution | Salt particulate matter ≤ 1.86 Oil particulate matter ≤ 1.60. |
Dynamic detection range | 0.001-100 mg / m³, accuracy: 1% |
Power Supply | Will match client’s local power supply requirements |
![]() |