Sign In | Join Free | My china-telecommunications.com
china-telecommunications.com
Products
Search by Category
Home > Engines >

Gasoline Stainless Steel Electromagnetic Flow Meter with Rubber Linging

Categories Electromagnetic Flow Meter
Model Number: MTF
Certification: CE/CMC/ISO9001
Place of Origin: China
MOQ: 1pc
Price: negotiation
Payment Terms: T/T or western Union
Supply Ability: 100pcs per month
Delivery Time: 7 working days after received your payment
Packaging Details: in wooden box
Brand Name: Metlan
Product Name: Gasoline Stainless Steel / Compact Type Electromagnetic Flow Meter
Model: MTF-FAP
Pressure: 4.0,1.6,1.0, 2.5MPa
Accuracy: ±0.2%
Output signal: 4-20mA,pulse,RS485
Liner: Hard rubber
Electrode: 316L,Hastelloy,Ti,Ta,PT
Power: 220VAC, 110VAC, 24VDC
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    Gasoline Stainless Steel Electromagnetic Flow Meter with Rubber Linging

    Gasoline Stainless Steel Electromagnetic Flow Meter with Rubber Linging


    The reason for choosing us


    1). It has the function of infrared remote control and button operation so as to make

    the operation more convenient.


    2). It provides the function of zero correction of sensor and automatic zero adjustment.


    3). It has multi-language interface to satisfy all the users’ requirements.


    4). It has the function of self-adjustment and self-checking.


    5). A variety of output communication interfaces are optional.HART communication (optional);

    RS485 (Modbus is optional) communication interface; Profibus (optional)

    16-figure current loop4~20mA output 0-10kHz frequency output Pulse equivalent output.



    Instrument detection and maintenance


    Electromagnetic flow converter has self-diagnosis function. In addition to the


    power and hardware circuit fault, The system also give alarm to other faults


    in general usage. These information are given accordingly prompts in the


    lower right of the screen.


    1, Maintenance and repair


    a) Sensor installation site should be consistent with the section four

    requirements, Please keep the housing clean and tidy;


    b)Transmitter should be placed in a clean, ventilated, dry place;


    c)Need to inspect every two years, for high precision users, instrument

    need to be submitted to censorship.


    2, Transportation, storage


    a)The instrument must be packed before transportation, be carefully

    handled when loading and unloading.


    b)Storage site must be dry, ventilated, avoid corrosive gas erosion, the

    ambient temperature is not too low or too high;


    c)Storage time better not exceed three years.


    3, Unpacking and checking


    a) The packing can’t be opened with heavy hammer, and should be


    careful not to damage the instrument


    b) Check the content carefully according to the packing list.




    Selectrion of Ground Ring


    If the pipe connecting to the meter is insulated,the ground ring is needed, generally

    metallic or non-metallic grounding rings or grounding electrode (non-metallic) material is

    available to adapt to the corrosion of the measured material.


    If the measured medium is abrasive, ground ring with neck should be used to protect

    lining material of two sides and to prolong its life.


    In order to make the reliable operation of the instrument, and to improve measurement

    accuracy, free from outside interference of Send potential,the sensor should have separate

    ground wire, and the ground ring of both sides of the sensors should be fitted when the

    ground resistance, in the pipe connecting to the sensor or non-metallic pipe, is less than 10Ω.




    MTF series magnetic flow meter selection table

    Type of instrumentMTF
    Installation form-SFlange-type sensor
    -DClamping-type sensor
    -CInsertion-type sensor
    Pipe diameter1515mm
    2020mm
    2525mm
    ........
    24002400mm
    Electrode form-FStandard and fixed type
    Electrode materialAStainless steel 316L
    BHb
    CTa
    DTi
    EHc
    FTungsten Carbide
    Gother
    Lining materialRRubber
    PPTFE
    OPlease mark out others
    Measuring pipe materialB304 Stainless steel (Standard)
    C316 Stainless steel
    Flange MaterialA304 stainless steel
    B316 Stainless steel
    C20# Carbon steel
    Cover MaterialDCover 304 stainless steel
    ECover 316 Stainless steel
    FCover Carbon steel paint (Epoxy metallic paint)
    Installation material flange0Without matching flange
    1With matching flange
    Ground ring0Without ground ring
    1With ground ring
    Rated voltage-101.0MPa
    -161.6MPa
    -404.0MPa
    Working temperatureE≦60℃
    H≦180℃(devided type)
    Form of converter-IIntegrated type
    -DDivided type
    Output signal and communicationPPulse
    A4-20mA
    G485 communication
    HHart communication
    QOthers
    Power supply0220V AC
    124V DC
    2Battery-powered
    Protection level0IP65
    1IP67(devided type)
    2IP68(devided type)
    Other featuresRHeat
    PWith PT1000
    BWithout PT1000
    Explosive proof level0Non-explosive proof
    EXEX

    Cheap Gasoline Stainless Steel Electromagnetic Flow Meter with Rubber Linging for sale
    Send your message to this supplier
     
    From:
    Enter your email please.
    To: Nanjing Metlan Measurement & Control Instrument Co., Ltd
    Subject:
    Message:
    Characters Remaining: (0/3000)
     