Sign In | Join Free | My china-telecommunications.com
china-telecommunications.com
Products
Search by Category
Home >

Petrochemical Industries Elevated Flare System For Oil & Gas Refinery With EPC Contracting Service

Categories Elevated Flare System
Brand Name: QIYAO
Certification: ISO, ASME, API
Place of Origin: China
MOQ: 1 set
Price: Customized Product, Quoted Case By Case
Payment Terms: T/T, L/C
Supply Ability: over 20 sets per year
Delivery Time: 36 - 48 weeks
Packaging Details: Seaworthy Packing
Material: Stainless Steel, Carbon Steel
Funtions: Safety measurs under emergency conditions and friendly to environment
Applications: Oil & Gas, Refinery, Petrochemical industries
Available service: Design, supply, site supervision on erection, commissioning, training.
Category: Elevated / Ground flare
Tip: Air assistant, Air force draft, sonic, etc.
Projects completed: over 400 sets
Packing: Seaworthy packing
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    Petrochemical Industries Elevated Flare System For Oil & Gas Refinery With EPC Contracting Service

    Petrochemical Industries Elevated Flare System For Oil & Gas Refinery With EPC Contracting Service


    Flare System is to handle the discharged combustible gas under the conditions of normal operation, start-up, shut-down and emergencies, which ensure the gas to be flared out instantaneously, safely and reliably and to meet the demand of environmental protection.


    Flare System is a kind of safety equipment comprised of pipeline, knock out device, fire retardant equipment, flare burner, ignition system, flare riser and other components.


    Flare Categories:

    * Based on the vent gas media’s physical parameters (mainly for toxicity of the vent gas media), discharge pressure, flow rate and so on, the flare shall be divided into two categories – elevated flare and ground flare.


    * The elevated flare, based on the support way, shall be divided into self-supported flare, inhaul supported flare and derrick supported flare. The derrick supported flare, based on types of the riser to be fixed, shall be divided into fixed derrick supported flare, demountable derrick supported flare.


    * The ground flare, based on vent gas treatment capacity, shall be divided into enclosed ground flare and open ground flare.


    * Based on structure of flare burner, the flare shall be divided into steam-assist flare, forced draft assist flare, defused flare, LHV flare, multi-hole collision flare, sonic flare, etc.


    Options of flare types

    Elevated flareGround flare

    ▽ Media attribute: unlimited


    ▽ Industry: unlimited

    ▽ Capacity: unlimited

    ▽ Media attribute: The media which is no extremely harmful.

    ▽ Industry: mainly focus on chemical field

    ▽Capacity: up to 150t/h for enclosed ground flare and unlimited for open flare


    Options of support way for elevated flare system:

    Self-supportedInhaulDerrick supported
    Fixed flareDemountable flare

    ▽Industry: Natural gas processing plant


    ▽Capacity: small

    ▽Height: not higher than 20m


    ▽Capacity: small

    ▽Height: up to 40m.

    ▽Industry: refinery, coal-chemical, LNG, off-shore, etc.

    ▽Capacity: large

    ▽Height: 40-160m

    ▽Application: The devices matching up the flare system need “same-time start-up & shut-down”

    ▽Industry: refinery, coal-chemical, LNG, off-shore, etc.

    ▽Capacity: large

    ▽Height: 40-160m

    ▽Application: The devices matching up multi sets of flare system can’t be “same-time start-up & shut-down”, need to reserve extra flare system for expansion and save land investment.


    Options of ground flare system

    Enclosed ground flare systemOpen ground flare system

    ▽ Media attribute: toxic flare gas, but not extremely or highly harmful

    ▽ Industry: focus on chemical industry

    ▽Capacity: not exceed 150t/h for single stack

    ▽Discharge pressure: up to 10kpag within BL (subject to the media)

    ▽Capacity: unlimited


    ▽Discharge pressure: up to 80kpag within BL (subject to the media)


    Options of flare burner


    Steam assist typeForced draft typeDiffused typeLHV typeMulti-hole collision typeSonic type

    Industry:

    Unlimited

    Media:

    Heavy Hydrocarbon

    Discharge pressure: lower, need assist for smokeless combustion

    ▽Utility: Steam available

    Industry:

    Unlimited

    Media: Heavy Hydrocarbon

    Discharge pressure: lower, need assist for smokeless combustion

    Utility: Non-steam

    Location: applicable for cold area.

    Industry :

    Coal chemical



    Media: LHV or hard-combustible media like sour gas or ammonia

    Industry:

    Natural gas

    Media: Light hydrocarbon composition

    Media:

    Off-shore platform


    Discharge pressure: Higher

    Defect:

    Noisy


    Working principle / flow process

    Elevated Flare System: The combustible gas is discharged from production equipment, flows into the battery limit of flare through vent pipe network, flows into the knock-out drum for separation of liquid drops probably contained in vent gas, flows into the water seal drum and breaks through the water seal, and then flows into the flare riser, goes through the molecular seal and finally is flared out by the burner.



    Specifications

    Process Data
    Flow rate of flare gas (min/normal/max)
    Composition of flare gas
    Temperature of discharged gas (℃)
    Back pressure of flare battery limit (Kpa)
    Utility Data
    Source of fuel gas
    Pressure & temperature of fuel gas
    Consumption of fuel gas (Nm3/h)
    Purge gasNitrogen
    Pressure & temperature of purge gas
    Consumption of purge gas (Nm3/h)
    Pressure & temperature of steam
    Consumption of steam
    Instrument air
    Pressure & temperature of instrument air
    Power supply380VAC / 50Hz / PH3
    Site Condition
    Ambient condition (design/operation)
    Min temperature
    Max temperature
    Humidity
    Max wind speed
    Main wind direction (Y/N) / direction
    Max solar radiation (W/m2)
    Flare radiation plus solar radiation (Y/N)
    Technical Requirement
    Design code & standardAPI537 / API521
    Flare type

    Elevated flare: self-supported / inhaul / fixed derrick supported / demounted derrick supported

    Ground flare: enclosed / open

    Aircraft warning light (Y/N)
    Smokeless combustion (Y/N)
    Method of smokeless combustionSteam / forced draft
    Requirement for thermal radiation
    Max ground thermal radiation
    Allowed thermal radiation at *m from sterile limit
    Requirement for noise
    Near the bottom of flare riser: xxdBA
    At *m from flare riser: xxdBA
    Burner
    Type of burnerSteam assist
    Design temperature(℃)/pressure(Kpag)1200 / Atmospheric
    Spec (Dia/H)
    Material310/304
    Outlet Mach number
    Resistance drop (Kpag)
    Muffler
    Windshield
    Flame stabilizer ring
    Smoke elimination measuresSteam assist / forced draft
    Size of smoke elimination interface
    Service life
    Molecular Seal
    TypeDynamic seal
    Design temperature(℃)/pressure(Kpag)1200 / Atmospheric
    Spec (Dia/H)
    Material304
    Resistance drop (Kpag)
    Service life
    Flare Riser
    Type
    Design temperature(℃)/pressure(Kpag)200 / Atmospheric
    Spec (Dia/H)
    Material
    Resistance drop (Kpag)
    Service life
    Pilot & Ignition System
    Pilot Qty
    TypeEnergy-saving
    Method of flame detectionThermocouple / Ultraviolet ray
    Type of ignition (manual / automatic)Sky ignition + Inner flame ignition
    Service life
    Water Seal Drum
    TypeFull water seal / semi water seal
    Design temperature(℃)/pressure(Kpag)
    Spec (Dia/H)
    Material
    Height of water seal
    Service life
    Knock-out Drum
    Type
    Design temperature(℃)/pressure(Kpag)
    Spec (Dia/H)
    Material
    Ability of knock out
    Service life
    Aircraft Warning
    Qty
    Position
    Color / Type (flash / beacon / paint)
    Demountable (Y/N)
    Code of painting

    Advantages

    1. Use international engineering software like FLARESIM, FLARENET, FLUENT, etc.;

    2. Own combustion test platform to simulate combustion conditions based on various types of flare gas;

    3. Own numbers of patent technologies and know-how;

    4. Have professional engineering design qualification;

    5. Have high-qualified engineering design team & research and development team;

    6. Have plentiful and comprehensive experiences of engineering construction;

    7. Have professional & high efficient after-sale service system.


    Typical Project

    22,000,000T/y Refinery Project at CNOOC Huizhou Refinery

    Phase #1 - 10,000,000T/y Refinery Project: The flare system consists of HP flare (DN1600), LP flare (DN1600) and Sour gas flare (DN500), and a reservation for DN1600 flare riser. The height of flare system: 150m.

    Phase #2 – 12,000,000T/y Refinery Project: Based on the reserved space of phase #1 for DN1600 flare riser and the optimized design of system, SMDERI took full advantage of “on-line assembly & system expansion” of the demountable common derrick flare to realize the reconstruction & expansion of phase #1 flare system and reach the target of multi-risers being set on a common derrick. For the best utilization of land, SMDERI provided his technical support so that the land investment was saved.

    The flare gas recovery system was equipped with a 20,000M3 Gas Holder, 2 units of 600,000M3 screw compressors and 2 units of 300,000M3 screw compressors.


    Patent Technology:

    l Demountable & common derrick elevated flare and its assembly & disassembly system (Utility Model Patent No.ZL200620048466.X)

    l The Assembly & disassembly system of demountable & common derrick elevated flare and its method of assembly & disassembly (Invention Patent No.ZL200610119032.9)

    l Staged discharge combustion system for combustible waste gas (Utility Patent No.ZL200620048087.0)

    l Staged discharge combustion system for combustible waste gas and its method of usage method (Invention Patent No.ZL200610118674.7)

    l Steam-assist flare burner (Invention Patent No.ZL200610118675.1)

    l Water seal structure for flare system (Invention Patent No.ZL200810041594.5)

    l Open ground flare (Utility Model Patent No.ZL201020529360.8)

    l Multi-side demountable & common derrick elevated flare (Utility Model Patent No.ZL201120233838.7)

    l New large stream of enclosed ground flare (Utility Model Patent No.ZL201120227204.0)



    Buy Petrochemical Industries Elevated Flare System For Oil & Gas Refinery With EPC Contracting Service at wholesale prices
    Send your message to this supplier
     
    *From:
    *To: Shanghai Marine Diesel Engine Research Institute
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Inquiry Cart 0