Categories | Main Propulsion Engine |
---|---|
Place of Origin: | China |
Brand Name: | Victory-Cummins |
Certification: | CE,SONCAP,IRAM,COC,CNCA,SASO |
Model Number: | CCFJ-100KW |
MOQ: | 1 set |
Price: | Discussible |
Packaging Details: | Polywood Package |
Delivery Time: | 30-45 Days |
Payment Terms: | TT, LC |
Supply Ability: | 500 sets/month |
Company Info. |
VICTORY POWER TECHNOLOGY Co.,LTD |
Verified Supplier |
View Contact Details |
Product List |
100KW 125KVA Cummins Marine Diesel Generator CCFJ - 100KW With CCS ZY BV 30KW To 800KW
Marine Generator
Model: CCFJ-100KW
Brand: Victory-Cummins
Rated power: 100 KW / 125 KVA
Rated speed: 1800 r/min
Connecting method: 3 phase and 4 wire
Power factor: 0.8LAG
Diesel engine
Model: 6BTA5.9-GM (4 stroke, Turbocharged & Intercooled,
Cooling by Heat Exchanger)
Brand: Cummins
Rated speed: 1800 r/min
Alternator
Brand: Stamford or Victory or other brand
Insulation: Class H
Marine auxiliaries:
With CCS and standard marine gen set configuration,
Without oil tank,
Without battery,
With sea water pump heat exchanger,
Double high-pressure tubing, fuel alarm system,
Digital controller,
Buzzer alarm.
Genset general feature:
1. Generator can be used as Main Marine generator, Marine emergency
generator or Harbor generator.
2. CCS, BV approved.
3. Cooled by heat exchanger / radiator.
6. Parallel connection: Two and more normal marine generating sets
can transfer loading without stoping
Them and can realiza parallel.
7. Standard SAE coupling the engine and alternator
8. With high efficiency anti-vibration devices
9. Cold rolled steel one time molded foundation.
10. High reliability, Global UNPROFOR, low fuel consumption, low
use and maintenance cost .
Walter-Cummins series use B, C, N, K series diesel engine from the
Cummins company, Chongqing Cummins and DongfengCummins. Power range
from 30 KW to 800 KW, is an ideal initiative power and backup
emergency power for all kinds of transportation ships.
This series have excellent startability and carrying capacity, with
low noise and low emissions, lower operating cost notable features.
The monitor and control system matching Genset can meet various
engine automatic requirements
The following parameters are for 1500 r/min Marine diesel
generating sets. If you need 1800 r/min and emergency Marine diesel
generating sets, please feel free to contact us.
Genset Model | Frequency (Hz) | Prime Power | Stanby Power | Current (A) | Voltage (V) | Engine Model | Engine Power(KW) | Rated Speed (rpm) | ||
KW | KVA | KW | KVA | |||||||
CCFJ-30KW | 50 | 30 | 38 | 35 | 44 | 54 | 400 | 4BTA3.9GM | 47 | 1500 |
CCFJ-35KW | 60 | 35 | 44 | 40 | 50 | 57 | 440 | 4BTA3.9GM | 65 | 1800 |
CCFJ-40KW | 50 | 40 | 50 | 45 | 56 | 72 | 400 | 4BTA3.9GM | 47 | 1500 |
CCFJ-45KW | 60 | 45 | 56 | 50 | 63 | 74 | 440 | 4BTA3.9GM | 65 | 1800 |
CCFJ-50KW | 60 | 50 | 63 | 55 | 69 | 83 | 440 | 4BTA3.9GM | 83 | 1800 |
CCFJ-55KW | 60 | 55 | 69 | 61 | 76 | 90 | 440 | 4BTA3.9GM | 100 | 1800 |
CCFJ-50KW | 50 | 50 | 63 | 55 | 69 | 90 | 400 | 6BT5.9GM | 83 | 1500 |
CCFJ-55KW | 60 | 55 | 69 | 65 | 81 | 90 | 440 | 6BT5.9GM | 100 | 1800 |
CCFJ-64KW | 50 | 64 | 80 | 75 | 94 | 116 | 400 | 6BT5.9GM | 83 | 1500 |
CCFJ-70KW | 60 | 70 | 88 | 80 | 100 | 115 | 440 | 6BT5.9GM | 100 | 1800 |
CCFJ-75KW | 50 | 75 | 94 | 83 | 104 | 135 | 400 | 6BT5.9GM | 83 | 1500 |
CCFJ-80KW | 60 | 80 | 100 | 92 | 115 | 131 | 440 | 6BT5.9GM | 100 | 1800 |
CCFJ-90KW | 50 | 90 | 113 | 100 | 125 | 162 | 400 | 6BTA5.9GM | 100 | 1500 |
CCFJ-100KW | 60 | 100 | 125 | 110 | 138 | 164 | 440 | 6BTA5.9GM | 120 | 1800 |
CCFJ-100KW | 50 | 100 | 125 | 110 | 138 | 181 | 400 | 6CT8.3GM | 115 | 1500 |
CCFJ-100KW | 60 | 100 | 125 | 110 | 138 | 180 | 440 | 6CT8.3GM | 129 | 1800 |
CCFJ-130KW | 50 | 130 | 163 | 150 | 188 | 235 | 400 | 6CTA8.3GM | 155 | 1500 |
CCFJ-130KW | 60 | 130 | 163 | 150 | 188 | 235 | 440 | 6CTA8.3GM | 175 | 1800 |
CCFJ-200KW | 50 | 200 | 250 | 220 | 275 | 361 | 400 | NTA855GM | 240 | 1500 |
CCFJ-250KW | 60 | 250 | 313 | 280 | 350 | 410 | 440 | NTA855GM | 287 | 1800 |
CCFJ-250KW | 50 | 250 | 313 | 280 | 350 | 451 | 400 | NTA855GM | 284 | 1500 |
CCFJ-270KW | 60 | 270 | 338 | 300 | 375 | 443 | 440 | NTA855GM | 313 | 1800 |
CCFJ-300KW | 50 | 300 | 375 | 330 | 413 | 542 | 400 | KTA19GM | 336 | 1500 |
CCFJ-350KW | 60 | 350 | 438 | 400 | 500 | 574 | 440 | KTA19GM | 392 | 1800 |
CCFJ-350KW | 50 | 350 | 438 | 400 | 500 | 632 | 400 | KTA19GM | 403 | 1500 |
CCFJ-400KW | 60 | 400 | 500 | 450 | 563 | 656 | 440 | KTA19GM | 463 | 1800 |
CCFJ-400KW | 50 | 400 | 500 | 450 | 563 | 722 | 400 | KTA19GM | 448 | 1500 |
CCFJ-450KW | 60 | 450 | 563 | 500 | 625 | 738 | 440 | KTA19GM | 507 | 1800 |
CCFJ-500KW | 50 | 500 | 625 | 550 | 688 | 903 | 400 | KT38GM | 560 | 1500 |
CCFJ-620KW | 60 | 620 | 775 | 680 | 850 | 1017 | 440 | KT38GM | 679 | 1800 |
CCFJ-600KW | 50 | 600 | 750 | 660 | 825 | 1083 | 400 | KTA38GM | 664 | 1500 |
CCFJ-750KW | 60 | 750 | 938 | 825 | 1031 | 1230 | 440 | KTA38GM | 809 | 1800 |
CCFJ-800KW | 50 | 800 | 1000 | 880 | 1100 | 1444 | 400 | KTA38GM | 880 | 1500 |